Model | NEMA Rating |
UL/CUL Listed or Recognized |
BTU/H Capacity |
95/95 Rating BTU/H |
Ambient Temp. | Volts | Hz | Running Amps |
Approx. Weight |
|||
°F | °C | |||||||||||
Max./Min. | Max./Min. | lbs | kg | |||||||||
FEDDERS-12345 | 12 | Listed | 1000 | 850 | 125/-20 | 52/-28 | 115/100 | 60/50 | 2.7 | 30 | 14 |
Rating shown is for operation at maximum ambient temperature.
This micro air conditioner is designed for small display cases in museums. It provided essential temperature and humidity control for artifacts and documents.
Features Include:
• Ball-bearing Motors
All blower motors are UL/CSA Recognized and include automatic-reset thermal overload protection and double-sealed or double-shielded precision ball bearings. Special permanent lubricants perform over a broad temperature range: -20°F (-29°C) to 250°F (121°C). Tube axial fans are rated to perform at 14°F (-10°C) to 158°F (70°C) and are designed to meet UL, CSA and VDE.
• CFC-Free Refrigerant
CFC-free R134a Refrigerant is used
• Closed Loop Cooling
The enclosure interior airflow system is isolated from the ambient airflow or waterflow system. No ambient air can invade the cool, dehumidified sensitive component compartment.
• Compressor Short Cycle Protector
Protects the compressor from possible damage due to harmful short cycling, (frequent starting) where temperature controls enable the compressor to restart frequently or after a power interruption. These conditions could be due to low or fluctuating heat loads within the electrical enclosure or a power failure. The Compressor Short Cycle Protector will prevent the compressor from starting when it has been shut off for less than several minutes or the power was interrupted. By limiting the number of compressor starts per hour, the life of the compressor is prolonged. It is recommended where installations are subject to solar gain and or changes in the enclosure internal load due to the degree of usage of the equipment being cooled. It is also recommended where higher capacity units are specified in anticipation of the future addition of heat producing equipment being added to the enclosure.
• Filter
All filters consist of a multi-layer grid of sturdy corrugated aluminum, securely held in a one-piece aluminum frame. Filters are required wherever air is drawn into an electronics enclosure or related cooling equipment to keep internal parts as clean as possible. A non-drying adhesive coating traps a high percentage of particulate matter. These filters are reusable, they may be washed and recoated with the appropriate filter recoating adhesive. Replacement filters are available and can be ordered online at kooltronic.com/spareparts.
• NEMA 12 Rating Maintained (UL50)
All units are fully gasketed for tight, leak-proof installation, in compliance with the NEMA 12 Enclosure Ratings.
• Programmable Thermostat
All models feature a programmable thermostat, allowing more accurate and versatile performance features.
• Temperature Alarm
A thermostat is mounted inside the cabinet and attached to a sensor in the warm air return. When the air temperature increases to the set point, a signal is sent to a terminal block. User-installed wiring from the terminal block to local and/or remote warning devices (light, bell, siren, etc.) can be for normally open or closed operation.
• UL/CUL Listed